HUBT-01P Helicobacter pylori tester

                        Product features: Innovative structural design, more compact, lighter, the latest circuit design and the latest components, lower background, higher efficiency, more reliable, fully automatic design, push and test, Free choice of measuring tim

                        Technical indicators: The detection efficiency of 14C non-quenching standard source should be ≥87%, and the counting rate of 14C background should be ≤60CPM. After the instrument has been working continuously for 48 hours, the relative change

                        Product advantages: Equipped with graphic workstations, can choose to print graphic reports, support scanning guns, support connection to the hospital network, automatically generate detection databases, convenient for query and call: especial

                        Back to list

                        InstructionsVideo presentationOnline documentationEquipment comparison table

                        01 The first step
                        Subjects should be tested on an empty stomach or two hours after eating, and take a urea [14C] capsule with about 20ml of cold drinking water.
                        02 The second step
                        Wait about 25 minutes (without strenuous exercise).
                        03The third step
                        Go to the medical staff to get the gas cylinder and disposable gas tube.
                        04 Step 4
                        Open the cap of the gas collecting bottle and insert the thin end of the blowing tube below the liquid level of the gas collecting agent bottle. The subject’s mouth contains the thickest end of the air-blowing tube and blows into the gas-collecting agent bottle with moderate and steady force. The air can be changed during blowing, but it is strictly forbidden to suck back. Do not spill liquid. Do not blow saliva into the air-gathering agent. The blowing time is 1~3 minutes. Stop blowing when the gas collector turns from purple to colorless. If the color fades after more than 3 minutes, you can also stop blowing, cover the bottle, and discard the disposable blowing tube. Designated place.
                        05 Step 5
                        The gas collector bottle is handed over to the examiner, waiting for the test result.
                        Video demonstration reference supporting equipment: HUBT-01P Helicobacter pylori tester
                        Comparison table of cassette and liquid scintillation equipment
                        Instrument type Detection principle Sampling material Detection efficiency Accuracy Repeatability Detection time Blowing force Blowing time Specimen effective gas Database Exterior market share
                        Liquid scintillation Photomultiplier Scintillation fluid >87% 94.60% >94% 1 minute easy 1-2 minutes 99% Have Simple 95%
                        Cassette Ionization Gas collection card >15% 85% >85% >4 minutes Strenuous 3-5 minutes 80% Have Simple and lightweight 5%